therapyTimes.com is a daily source for Music, Nursing, Nutrition, Occupational, Pediatric, Physical, Respiratory and Speech Therapy Professionals containing editorials, articles and radiology jobs.

Music Therapy, Nursing, Nutrition Therapy, Occupational Therapy, Pediatric Therapy, Physical Therapy, Respiratory Therapy, Speech Therapy




search site:    
 


home | login | register





:: Animals Linked to Human Chlamydia Pneumoniae

:: Obstructive Sleep Apnea May Worsen Diabetes

:: Respiratory Weakness in ICU Morbidity

:: Doubts About the Accepted Origin of Pulmonary Embolism

:: Sleep Apnea Duration More Affecting Than Severity

:: Dendritic Cells Spark Inflammation in Smokers’ Lungs

:: Risk Factors For Sleep Disordered Breathing In Children: Waist Size And Body Mass Index

:: Air Pollution in Tunnels Concentrated by up to 1000 Times

:: Potential For A Fast, Accurate Urine Test For Pneumonia

:: Even Healthy Lungs Labor At Acceptable Ozone Levels

:: Adults With Asthma Not Getting Their Flu Shots

:: Inappropriate Sepsis Therapy Leads to Fivefold Reduction in Survival

:: How Coughing is Triggered by Environmental Irritants

:: Noninvasive Ventilation Should be Used in Epidemics

:: Common Surgical Procedure Effective Treatment for Sleep Apnea

:: Self-Treatment Results in Lower Overall Healthcare Costs for COPD Sufferers

:: Study Finds Link Between Parental Stress, Air Pollution, And Children’s Risk For Developing Asthma

:: How Carbon Nanotubes Can Affect Lining of the Lungs

:: Patients with CRS Have Increased Incidence of Other Chronic Illnesses

:: Breathe Easy

:: Discovery Of Increased ‘Sibling Risk’ Of Obstructive Sleep Apnea In Children

:: Researchers Track Down Protein Responsible for Chronic Rhinosinusitis with Polyps

:: Predicting the Risk of Death in COPD May Help Physicians to Individualize Treatment

:: Air Pollution Linked To Hospitalizations For Pneumonia In Seniors

:: What Happened to the Flu?

:: Swine Flu Fears Close More Summer Camps

:: Yoga Helps Asthma Patients In 10 Weeks

:: Cell Phones Will Help Scientists Monitor Air Pollution in San Diego

:: Gene Stops Excess Mucus in Respiratory Disease

:: Respiratory Failure in Patients with Chronic Respiratory Disorder

:: American Lung Association Calls For Tighter Nitrogen Dioxide Air Pollution Standard

:: Breathlessness Eased in Patients with Rare, Often Fatal Disease

:: Beyond Tradition

:: Need for Emergency Airway Surgery for Hard-to-Intubate Patients Reduced

Emergency Medical Record



::  Occupational Therapist-Outpatient | US - TX
::  Occupational Therapist-Rehab | US - OH
::  Occupational Therapist-Rehab | US - TX
::  Occupational Therapist-School | US - AR
::  Occupational Therapist-School | US - TN
::  Occupational Therapist-Skilled | US - TX
::  Licensed Physical Therapists and Physical Therapy Assistants | US - NY
::  Occupational Therapists and Occupational Therapy Assistants | US - NY
::  Home Care Physical Therapists | US - CT
::  OCCUPATIONAL THERAPISTS (WHEELING, IL) | US - IL
::  Physical Therapy Jobs
By Onward Healthcare
  [more]

   
home :: departments :: journal watch

Detecting Disease Using Portable, Precise Gas Sensor
09.29.09

Article available online at: http://www.therapytimes.com/092909Respiratory


In the air, it is a serious pollutant. In the body, it plays a role in heart rate, blood flow, nerve signals and immune function.

Nitric oxide, a gas well known to scientists for its myriad functions, has proven challenging to measure accurately outside the laboratory. A team of New Jersey-based Princeton and Texas-based Rice University researchers has demonstrated a new method of identifying the gas using lasers and sensors that are inexpensive, compact and highly sensitive. Such a portable device, suitable for large-scale deployment, could be of great value to atmospheric science, pollution control, biology and medicine.

Nitric oxide is so potent that a few molecules of it per billion, or even trillion, molecules of air promote smog, acid rain and depletion of the ozone layer. Similarly tiny amounts in a patient’s breath could help diagnose asthma and other disorders.

The researchers believe their device could find uses ranging from the study and control of car and truck emissions to monitoring human exposure to pollutants in urban and industrial environments. For medical uses the device is particularly attractive because the results are not corrupted by water vapor, which is present in breath samples. Testing for nitric oxide in a patient’s breath, for example, could reveal chronic obstructive pulmonary disease and inflammation.

“The sensor we’ve developed is much more accurate and sensitive than existing systems, yet is far more compact and portable,” says Gerard Wysocki, PhD, assistant professor of electrical engineering at Princeton.

Wysocki is a co-leader of a team that developed the system and conducted preliminary tests during the 2008 Olympic Games in Beijing. The team included Rice researchers Frank Tittel, PhD, and 1996 Nobel laureate Robert Curl, PhD, both pioneers in the field of molecular detection using lasers, as well as Rafał Lewicki and James Doty III, also of Rice. The team published its results in the Aug. 4 issue of the Proceedings of the National Academy of Sciences.

With improvements made after the Beijing test, the system could be made into a portable, shoe-box-sized device ideally suited for mass deployment in large-scale unattended sensor networks for global, real-time, continuous monitoring of nitric oxide and other gases present in trace amounts.

Existing systems to detect nitric oxide and other trace gases have a variety of drawbacks. Some, such as carbon monoxide sensors for homes, are compact and inexpensive, but not very sensitive. These sensors can at best detect gases at parts-per-million concentrations – they can’t handle the parts-per-billion level, let alone the parts-per-trillion level that some applications require. High-end systems, such as mass spectrometers and gas chromatographs, are much more sensitive, but are slow, bulky, complicated and expensive – and impractical for use outside of a lab.

Of intermediate sensitivity are optical systems that pass a laser beam through a gas sample and detect whether some of the laser light is absorbed by the gas sample. A weakness of this method is that the amount of absorption is very small compared to the overall amount of laser light, so the signal is hard to detect. Further, conventional optical sensors tend to be bulky, use large amounts of the sample, and require frequent operator intervention.

The new system developed by Princeton and Rice researchers uses optical sensing as well, but produces a much stronger signal. In their setup, the researchers passed the laser light through polarizing filters that block all light unless nitric oxide is present. Roughly speaking, the more nitric oxide, the more light makes it through the filters, Wysocki says. “There’s no background signal to worry about.”

Nitric oxide detectors have used similar methods before, but until now have been hampered by their reliance on large laser sources designed for laboratory use, he says. The new system, in contrast, uses a quantum cascade laser, a state-of-the-art device ideally suited for this sensing technique. This makes it possible to reliably detect the gas at a concentration of a few parts-per-billion. The device is so precise it can distinguish between different isotopes of nitrogen and oxygen in the nitric oxide molecules.

“It’s remarkable we have that kind of sensitivity,” says Curl, who laid the groundwork for the detection technique in a paper he co-wrote with Tittel nearly 30 years ago.

“A portable sensor that can continuously measure nitric oxide with such high sensitivity is a real breakthrough,” says Tittel.

Unlike other systems that need several liters of the sample gas, the new sensor needs only a few milliliters of it, inside a container just about 16 inches long and a half-inch in diameter. This frugality is particularly important in delicate biological applications such as cell-culture studies, says Wysocki. Also important, the new system can run much longer without intervention – several hours compared to just a few minutes for even the best existing ones – which will allow for long-term unattended operation.

Princeton researchers are working on various enhancements to the technology, further shrinking the size of the device and exploring an even more sensitive method of analysis called coherent detection. “This technique could help us achieve parts-per-trillion sensitivity,” Wysocki says.

Source: Princeton University, Engineering School



  Have a comment on this article? Send it




Interactive Metronome at CSM 2010
Al Guerra discusses the benefits of the IM Gait Mate, which consists of a wireless shoe insert that is activated when an individuals heel strikes the ground. A constant reference tone can be heard through wireless headphones set to a desired gait speed; additional, real-time auditory feedback is given to direct the user if their speed is too fast, too slow, or right on.
[webcast archive]

 
Copyright © 2010, Valley Forge Publishing Group
2570 Boulevard of the Generals, Ste 220, Norristown, PA 19403
p. 800-983-7737 | f. 610-854-3780 | e. info@therapytimes.com
 
Web Award   APEX Award   ASBPE Award   ASHPE Award